Mixed Flow Fan
Mixed Flow Fan EKD Series
Mixed Flow Fan Description
– New built-in deflector design, maximum air volume 4160m3/h, maximum static pressure 1200Pa.
– It adopt a brushless DC motor with built-in intelligent control module.
– The interface size is 200-400mm, and six air volumes are available for optional.
– Widely used in ship equipment and other fields.
EC Motor Features
– It comes with +10V output and 0-10Vdc/PWM input interface, which can realize infinite speed adjustment or centralized intelligent control.
– Speed signal output interface enables real-time monitoring of speed.
– Intelligent adjustment, high efficiency and energy saving, low noise and long continuous operation time.
– Universal 50/60Hz power supply.
Model Description

General Fan Facts Description
• The fan is used for transportation of "clean" air, meaning not intended for fire-dangerous substances, explosives, grinding dust, soot, etc.
• The fan is equipped with an asynchronous external rotor induction motor with maintenance-free sealed ball-bearings.
• The capacitor has finite lifetime and should be exchanged after 45,000 hours of opera-tion (about 5 years) to secure maximum function. Defective capacitor can cause damage.
• To achieve maximum life time for installations in damp or cold environments, the fan should be operating continuously.
• The fan can be installed outside or in other damp environments. Make sure that the fan-house is equipped with drainage.
• The fan can be installed in any position.
Installation
• The fan must be installed according to the air direction label on the fan.
• The fan must be connected to duct or equipped with a safety grille.
• The fan should be installed in a safe way and make sure that no foreign objects are left behind.
• The fan should be installed in a way that makes service and maintenance easy.
• The fan should be installed in a way that vibrations can not be transfused to duct or building.
• To regulate the speed, a transformer, a triac or a frequency converter can be connected.
• A wiring diagram is applied on the inside of the junction box or separately enclosed.
• The fan must be installed and connected electrically in the correct way grounded.
• Always use the internal thermocontact, see wiring diagram.
• Electrical installations must be made by an authorized electrician.
• Electrical installations must be connected to a locally situated tension free switcher or by a lockable head switcher.
Operation
When starting, make sure that:
• The current does not exceed more than +5% of what is stated on the label.
• The connecting voltage is in between +6% to –10% of the rated voltage.
• No noise appears when starting the fan.
• The rotation direction at 3-phase motors are according to the label.
Maintenance
• Before any maintenance or cleaning, switch off the fan and make sure it can not be switched on again accidentally.
• The fan must be cleaned regularly to maintain its performance.
• Do not use water or aggressive cleaning agents. Use a dry or slightly damp cloth.
• Check the impeller and motor for wear and damage during maintenance.
• Replace defective parts only with original spare parts from the manufacturer.
Warranty
• The manufacturer provides a 24-month warranty from the date of purchase.
• The warranty covers defects in materials and workmanship under normal use.
• The warranty does not cover damage caused by improper installation, misuse, or lack of maintenance.